Back to Projects Penthouse Cali
Structural Retrofit Residential — Cali, Valle del Cauca

Penthouse Cali

Structural retrofit, roof design and addition

Structural Design Seismic Analysis ETABS NSR-10

Key Highlights

  • Design of a penthouse addition
  • Three structural drawing sheets E-01, E-02, E-03
  • Collaboration with the architecture team
  • Retrofit of the existing confined masonry to support a new level

Technical Specifications

Structural System
Reinforced concrete moment-resisting frames
Codes & Standards
NSR-10
Software
ETABS
Foundation
Foundation for the addition

Engineering Challenge

The existing 2-story confined masonry structure did not meet the requirements of the current NSR-10 code, having been built long ago. The project required evaluating its existing capacity and designing the entire structural system from scratch — from the foundation to the roof — using a moment-resisting frame system to ensure compatibility with the existing walls and compliance with Cali’s seismic requirements.

Location

Cali, Valle del Cauca

Consolidated urban area in a high seismic hazard zone (Cali — Av. II). Work within an existing residential fabric, with restricted site access and operations.

Role

Comprehensive structural design: diagnosis of the existing system, modeling and verification in ETABS under NSR-10, design of the retrofit, the roof and the new penthouse level, and preparation of structural drawings for the building permit.

Process

Design of the third level as a complete apartment New structural system integrated with the existing one Design of the transition floor slab Optimization of dead loads on the upper level Lightweight roof over the penthouse level Design of the roof support elements Control of wind, rain and impact loads Compatibility with the new load-bearing system

Results

  • Habitable level delivered as a complete penthouse on top of the existing confined masonry structure
  • 4 columns strengthened with concrete jacketing to increase their shear and flexural capacity
  • Maximum drift verified below 1% of story height (h_pi) in both directions, meeting NSR-10
  • New foundation designed with 1.2×1.2 m footings, integrated with the existing system
  • Lightweight roof designed for wind, rain and impact loads
  • Complete documentation ready for the building permit

Lessons Learned

Diagnosis is the most critical stage. In existing masonry structures, the quality of the initial information about the confining system and the foundation completely determines the feasibility of the design. An incomplete survey can invalidate weeks of calculations.

ETABS Analysis (6)

ETABS model 01 – Penthouse Cali
ETABS model 01 – Penthouse Cali
ETABS model 02 – Penthouse Cali
ETABS model 02 – Penthouse Cali
ETABS model 03 – Penthouse Cali
ETABS model 03 – Penthouse Cali
ETABS model 04 – Penthouse Cali
ETABS model 04 – Penthouse Cali
ETABS model 05 – Penthouse Cali
ETABS model 05 – Penthouse Cali
ETABS model 06 – Penthouse Cali
ETABS model 06 – Penthouse Cali

Structural Drawings (3)

Structural drawing 01 – Penthouse Cali
Structural drawing 01 – Penthouse Cali
Structural drawing 02 – Penthouse Cali
Structural drawing 02 – Penthouse Cali
Structural drawing 03 – Penthouse Cali
Structural drawing 03 – Penthouse Cali